Monitor. Analyze. Optimize.

THE PLATFORM

One Operational View Across Your Factory

Connect plant-floor equipment, energy infrastructure and industrial data in a secure On-Premise platform.

CAPABILITIES

Built for the Reality of Industrial Operations

Explore any capability card below to inspect architecture, industrial protocols, live telemetry, and verified factory case studies.

01

SCADA Monitoring

Monitor machines, equipment and sensors in real time.

02

Energy Monitoring

Track electrical consumption, demand and energy performance.

Active Detail

03

Power Quality

Analyze voltage, current, frequency, harmonics and power quality.

04

Sensor Analytics

Visualize analog and digital sensor data with historical analysis.

05

Alarms & Alerts

Act on critical conditions with clear, configurable alarm workflows.

06

Industrial Synoptics

Build interactive 2D and 3D views for machines and processes.

IEEE 519 & EN 50160 COMPLIANCEIEEE 519-2022 Harmonic LimitsEN 50160 Grid Quality

Power Quality

Harmonic Distortion Spectral Analysis, Microsecond Voltage Sag Recording & Power Factor Optimization

Modern variable frequency drives (VFDs), servo systems, robotic arms, and induction furnaces generate non-linear currents that distort factory voltage waveforms. RockLyzor Power Quality performs Class A continuous monitoring to analyze Total Harmonic Distortion (THD) up to the 63rd order, capture voltage sags and swell transients, and maintain power factor correction banks to shield sensitive CNC machinery from costly failures.

Compliance:IEEE 519-2022 Harmonic LimitsEN 50160 Grid QualityIEC 61000-4-30 Class A MeasurementIEC 61000-4-7 Harmonics

Live Telemetry State

Continuous Industrial Scan

On-Prem Engine OK

Voltage THD (V-THD)

1.74 %

IEEE 519 limit < 5.0%

Current THD (I-THD)

5.82 %

Within distribution limits

Power Factor (cos φ)

0.984 Lag

Zero reactive billing penalty

Voltage Unbalance

0.38 %

IEC limit < 2.0%

Bus cycle frequency: 50msData loss protection: Active

Core Architectural Features

Enterprise-grade functionality engineered for plant-floor reliability

01

Harmonic Spectral Decomposition

Continuous Fourier analysis of phase voltages and line currents from the 1st through the 63rd harmonic order, isolating critical 5th, 7th, 11th, and 13th harmonic currents that overheat transformer windings.

Identifies resonance and filter degradation before equipment trips
02

High-Speed Sag & Swell Transient Capture

Sub-cycle RMS evaluation (< 10ms trigger) detecting grid switching transients, lightning surges, and voltage sags caused by heavy motor startup across the municipal feeder.

Microsecond event capture with full COMTRADE waveform oscillography
03

True Power Factor & Displacement (cos φ)

Accurate decomposition of active (kW), reactive (kVAR), and apparent (kVA) power with automated step recommendation for power factor correction capacitor banks to eliminate utility penalties.

Keeps average power factor above 0.98 lagging
04

Voltage Unbalance & Neutral Loading

Continuous computation of Voltage Unbalance Factor (% VUF) and zero-sequence triplen harmonic currents (3rd, 9th, 15th) circulating in neutral conductors, preventing motor derating.

Guarantees unbalance remains under the strict 2.0% IEC limit

Industrial Protocols & Interfaces

Native multi-vendor communication without third-party OPC middleware licenses or external bridges.

Modbus TCP (High-speed Waveform Registers)IEC 61850 MMS (Substation Automation)DNP3 over TCP/IPFTP Waveform COMTRADE DownloaderIEEE 1159 Event Log IngestionSerial RS-485 Power Quality Transducers

Air-Gapped OT Network Architecture

Runs entirely within local manufacturing subnets (VLANs). No cloud uplink required for operations or real-time HMI rendering.

Technical Specifications

Deterministic performance metrics verified on industrial server environments.

Class A ComplianceIEC 61000-4-30 Edition 3 Class A precision
Harmonic Measurement1st to 63rd harmonic order (THD-V and THD-I)
Sampling ResolutionUp to 512 samples per electrical cycle (25.6 kHz)
Sag/Swell ThresholdsConfigurable 10% to 90% sag, 110% to 180% swell
Waveform FormatIEEE C37.111 COMTRADE (Common Format for Transient Data Exchange)
Grid StandardsAutomated EN 50160 & IEEE 519-2022 weekly compliance verification
Verified Factory Case StudyIndustry: High-Precision Aerospace CNC Machining

Operational Challenge

Random spindle drive inverter faults and transformer insulation overheating caused catastrophic scrap events averaging $62,000/month with zero diagnostic clues.

RockLyzor Deployment

Installed RockLyzor Power Quality continuous monitoring on main 400V busbars with automated harmonic threshold traps.

Measured Results

  • Uncovered 5th harmonic resonance created by a degraded passive harmonic filter within 48 hours
  • Prevented imminent burnout of two 1,250 kVA primary dry-type transformers
  • 12 consecutive months of zero harmonic-related spindle drive trips
Switch Capability:

DEPLOYMENT

Control Stays Inside Your Infrastructure

RockLyzor is deployed On-Premise, close to the systems it monitors. Your teams retain control of data, network architecture and access.

Local network deployment

Industrial protocol integration

Role-aware monitoring access

Start with your operation

Ready to See Your Factory Differently?

Discover how RockLyzor can centralize your industrial data and give your team real-time operational visibility.